본문 바로가기

실험/장비

80m 교량거더 실험, 12m 건축구조물 실험, 20,000kN 압축실험이 가능한 대형 실험시설과 첨단 유압 가력 및 제어 시스템을 갖춘 세계적 구조실험 인프라입니다.

실험장비

정/동적 유압가력기(Actuator) 정/동적 유압가력기
(Actuator)

정/동적 유압가력기(Actuator)
Classification Quantities Capacity Stroke Piston Rod Velocity
20 kN Dynamic Actuator 1 ±20kN 150mm 400mm/s
20 kN Dynamic Actuator 2 ±20kN 200mm 400mm/s
100 kN Dynamic Actuator 1 ±100kN 250mm 200mm/s
160 kN Dynamic Actuator 1 ±160kN 250mm 100mm/s
250 kN Dynamic Actuator 2 ±250kN 750mm 1,000mm/s
500 kN Dynamic Actuator 1 ±500kN 250mm 40mm/s
500 kN Dynamic Actuator 2 ±500kN 250mm 160mm/s
1,000 kN Dynamic Actuator 2 ±1,000kN 800mm 400mm/s
2,000 kN Dynamic Actuator 2 ±2,000kN 1,000mm 150mm/s
3,000 kN Dynamic Actuator 1 ±3,000kN 700mm 300mm/s
5,000 kN Static Actuator 2 +3,500kN
-5,000kN
2,000mm 16mm/s

UTM(Universal Test Machine) UTM
(Universal Test Machine)

20,000kN Dynamic UTM

  • · Max. Capacity Force : +20,000kN, -13,500kN
  • · Max. Capacity Stroke : 750mm
  • · Testing Space : 15.0(L)×5.5(W)×9.0(H)
  • · Max. Rate of Stroke : 80mm/s

5,000kN Dynamic UTM

  • · Max. Capacity Force : ±5,000kN
  • · Max. Capacity Stroke : 500mm
  • · Testing Space : 3.0(L)×1.5(W)×6.0(H)
  • · Max. Rate of Stroke : 40mm/s

5,000kN Static UTM

  • · Max. Capacity Force : ±5,000kN
  • · Max. Capacity Stroke : 500mm
  • · Testing Space : 4.0(L)×1.0(W)×4.0(H)
  • · Max. Rate of Stroke : 4mm/s

100kN Static UTM

  • · Max. Capacity Force : ±100kN
  • · Max. Capacity Stroke : 600mm
  • · Testing Space : 0.2(L)×0.5(W)×0.7(H)
  • · Max. Rate of Stroke : 5mm/s

계측장비 계측장비

Static DAQ System

Static DAQ System

  • - TDS-530 & Switching Box SSW-50D
  • -총 190 채널(50Hz/ch)
Static DAQ System

Dynamic DAQ System

  • - IMC CRONOS PL 16
  • - 총 320 채널(10~1,000kHz/ch)
Amplifier Module Quantities Total Channels Measurable Physical Quantities
8 Channels(Multi-purpose) (CRPL/UNI-8) 8 64 Strain, Displacement, Temperature, Load, Vibration, Voltage, Pressure
8 Channel(Bridge&Voltage) (CRPL/DCB-8) 22 176 Strain
8 Channels(Temperature) (CRPL/C-8) 5 40 Temperature
8 Channels(Voltage) (CRPL/LV2-8) 5 40 Voltage, Vibration
Static DAQ System

Hybrid DAQ System

  • - AMT-PL 660
  • - 총 72 채널(800kS/s for 6000, 7MS/s for HS System)
Static DAQ System

Laser Extensometer

Model Measurement Range Resolution
LX 500 8 - 127mm 0.001mm
LX 1500 13 - 380mm 0.01mm